2008 Annual Meeting
(139e) Properties and Characterization of Pharmaceutical Powders Modified by Dry Coating
Authors
Positron Emission Particle Tracking (PEPT) was used as a tool to determine the differences in mobility of powders with no additive compared to powders that had been coated with a specific level of additive using the Magnetically Assisted Impaction Coater . PEPT is a tool derived from the positron emission tomography (PET) nuclear technology used in medical imaging. Instead of imaging as with PET, PEPT uses the same triangulation principle to track a positron emitting tracer particle. The triangulation principle works using the pairs of gamma rays emitted from the particle to track the exact location of the particle at that time. Previous results indicate that increasing the level of additive caused an increase in the flowability and mobility of the powder. PEPT was used as a tool to quantify the increase in mobility of the powder.