Breadcrumb
- Home
- Publications
- Proceedings
- 2019 Spring Meeting and 15th Global Congress on Process Safety
- The 31st Ethylene Producers
- Ethylene Plant Maintenance & Reliability
- (120f) Induced Draft Fan Reliability Case Study
This paper discusses a case study involving an ethylene furnace induced-draft (ID) fan that suffered reliability issues resulting in unplanned plant shutdowns leading to estimated $18 million in lost opportunities. We will explain some of the symptoms that the induced draft fan may have experienced that could have resulted in the unplanned furnace shutdown. Finally we will also describe the design changes that were made to the new ID fan using the design features of API-673 fan specification and improved the ethylene furnace overall reliability.