Many companies put FAR too much redundant effort into determining what SIL (safety integrity level) is needed and then verifying the SIF (safety instrumented function) design will give the SIL targeted. This paper shows how to apply the qualitative definition of independent protection layers (IPLs) within the setting of a process hazard analysis (PHA) to get most of the gain from Layer of Protection Analysis (LOPA) without doing a LOPA (without using numerical values). We show how we use a PHA team to identify when a SIF is needed and to select the proper target SIL. This portion of the SIL evaluation and the identification and labeling of the IPLs during the PHA/HAZOP does not take any longer than a normal PHA/HAZOP, once the right habits are established. Note that this approach eliminates the need for a separate SIL Evaluation Study to identify the SIFs and select the target SIL. Then, this paper describes how to perform the SIL Verification and Safety Requirements Specification (SRS) remotely, again without the need for a redundant team meeting. This approach has been used at many sites and for thousands of SIFs.