2016 AIChE Spring Meeting and 12th Global Congress on Process Safety
(185a) Refinery Wastewater Treatment for 'zero Liquid Discharge'
Author
Sajja, V. S. K. - Presenter, Auburn University
Entire wastewater from a large refinery was selectively treated for oil removal, then for BOD/COD removal and comingled with freshwater cooling tower blowdown. After equalization of the streams divalent cation were reduced by physical chemical treatment followed by multi-pass multistage Reverse Osmosis membrane process. Reverse Osmosis brine was further treated with falling film thermal evaporator. More than 95% of the water was recovered.