2015 AIChE Spring Meeting and 11th Global Congress on Process Safety

(136a) Phi Correction for Exothermic Gas Generation Rate

Design of emergency relief systems to accommodate runaway reactions often requires using bench-scale adiabatic calorimeters to evaluate thermo-kinetic data of a full-scale reactor. The method to correct dT/dt from bench-scale experimental data to a full-scale reactor, phi correction, was well established. This study developed a similar method to correct exothermic gas generation rate from bench-scale data with a high phi factor to a full-scale reactor (phi = 1), which can be used for emergency relief system design. The technique was applied to a study of the real case emergency relief system design.