This paper reports the use of an intermediate filter layer to remove unwanted phases from real-time analysis. Removing this interference has been shown to dramatically reduce signal noise for binary and ternary phase systems by selectively passing only one of the phases to the sensing region of the PAT probe. Because of the local continuous phase separation [1], we evaluated the potential impact of sensor delay. Fortunately, we found the observed sensor delay to be insignificant relative to typical reaction times. For a desired analyte, the theory guiding the selection of filter material based on surface energy and porosity will be discussed, as well as opportunities for improvement and implementation on a manufacturing scale.
References:
[1] Kralj, J.G.; Sahoo,H. R.; Jensen, K. F., Integrated continuous microfluidic liquid-liquid extraction Lab Chip 2007, 7, 256–263