Breadcrumb
- Home
- Publications
- Proceedings
- 2011 Annual Meeting
- Separations Division
- Membranes for Bioseparations I
- (466e) Application of Membrane Technologies for Biomolecules Separation by Affinity Binding to Recovered Stereospecific Ligands
In this study, we intended to investigate the separation performance of D,L-tryptophan by utilizing Human Serum Albumin (HSA) as the stereoselective ligand. HSA was chosen due to its ability to undergo a structural change under different solution pH. The trend in D,L-tryptophan separation performances after several regeneration cycles of HSA was analyzed and it was found that the native and recovered HSA molecules exhibit a similar D,L-tryptophan separation factor of 5-7. Other than reusability, a high recovery of stereoselective ligand after each separation process is also substantial. For this purpose, low fouling tendency polyethersulfone (PES) hollow fiber membranes with a high rejection of HSA was fabricated by a non solvent induced phase inversion process. We observed that by controlling membrane pore size and hydrophilicity, a high recovery percentage of HSA of above 80% could be attained.