In this work, we develop a first principles model that incorporate fluid mechanics, mass transfer and surface reaction/ diffusion mechanism to describe stagnant as well as convective flow biosensing system. A set of coupled partial differential equations with proper boundary conditions are derived based on first principles model (such as equation of continuity for mixtures with reaction term) for different geometries and flowing conditions. Numerical solver COMSOL Multiphysics® 3.4 has been used to solve the 3D/2D system. COMSOL results are validated by the analytical results for simplified geometries (such as hemisphere, disk etc) with stagnant flow to ensure the model correctness when applied to more complex systems. The dynamics of biosensing with more realistic sensor geometry (such as rectangular bar) in 2D and 3D forms are investigated. For the detection of bacillus anthracis spores using phage-based magnetoelastic biosensors, analysis of simulation results reveals that the binding ratio is 2:1 for antigen and bacteriophage, instead of typically observed 1:1 binding for antigen and antibody binding [4]. This finding is verified by experiments. In addition, simulation results indicate that the reverse binding constant is higher than forward binding constant, which is also verified by experiments. To optimize the performance of the biosensor, biosensing dynamic response are analyzed and the effects of different factors such as mass transfer, bulk concentration, reaction mechanism and binding constant are investigated. The methodology and results obtained in this work can be used to guide biosensor design to optimize sensitivity. In addition, this work demonstrates how the numerical simulation can help us understand the biosensing mechanism.
Reference:
1. Sheehan P. E., and Whitman L. J., ?Detection limits for nanoscale biosensors?, Nano Letters, 5(4), 803-807, 2005
2. Wan J., Shu H., Huang S., Fiebor B., Chen I., Petrenko V., and Chin B., ?Phage-Based Magnetoelastic Wireless Biosensors for Detecting Bacillus Anthracis Spores? IEEE Sensor Journal, 7(3), March 2007
3. Wan J., Johnson M., Guntupalli R., Petrenko V., and Chin B., ?Detection of Bacillus anthracis spores in liquid using phage-based magnetoelastic micro-resonators?, Sensors and Actuators B 127 (2007) 559?566
4. Hua G., Gaob Y., Li D.,?Modeling micropatterned antigen?antibody binding kinetics in a microfluidic chip? Biosensors and Bioelectronics 22 (2007) 1403?1409