In the batch reactor system, the volumetric mass transfer coefficient has been increased several times when mechanical agitation is accompanied with ultrasound irradiation. However, the capillary microreactor was superior to the batch reactor system under the different operational conditions.
With respect to the capillary microreactor, it was found that the mass transfer performance was enhanced under sonication conditions more profoundly than under silent conditions. Under sonication conditions, the mass transfer performance was further enhanced by increasing the aqueous-to-organic phase flow rate ratio.