2008 Annual Meeting
(115f) Alternate Methods for Eluting Cesium from Spherical Resorcinol-Formaldehyde Resin
Authors
Alternate methods for eluting the resin have been tested, including using lower concentrations of nitric acid, other acids, and changing the flow regimes. All of these laboratory-scale tests used a 1.5-cm inside diameter column with a resin height of 10.5 cm, the same aspect ratio as the planned SCIX columns. The resin was loaded with 9.5 g Cs/L of resin prior to elution, which is the maximum expected loading for RF resin treating the waste at SRS.
The alternative method that used 4 BV of 0.5 M HNO3 followed by 13 BV of 0.05 M HNO3 used 164 g of nitrate per liter of resin (35% of the standard elution) and removed >99.996% of the cesium. Formic acid was slightly less efficient than nitric, but 20 BV of 0.5 M HCOOH removed 99.98% of the cesium.