Breadcrumb
- Home
- Publications
- Proceedings
- 2007 Annual Meeting
- Separations Division
- Membranes for Bioseparations I
- (244e) Ultrafiltration of Parvovirus
Tangential flow ultrafiltration and high performance tangential flow filtration of Aedes Aegypti densonucleosis virus has been investigated using flat sheet membranes with a nominal molecular weight cut off of 30, 50, 100 and 300 kD. Virus particles were detected in the permeate of the 300 kD membrane for both modes of operation. In tangential flow filtration no virus particles were detected in the permeate from the 100 kD membrane. However, during high performance tangential flow filtration significant passage of virus particles through the membrane was observed. The results obtained here are in general agreement with results obtained in previous studies of high performance tangential flow filtration for protein purification. Optimization of the operating conditions of high performance tangential flow filtration may result in a highly selective unit operation for purification of virus particles and virus vectors.