2006 AIChE Annual Meeting
(5bs) Initiated Chemical Vapor Deposition of Thin Polymeric Coatings
Authors
In this study, the kinetics associated with the iCVD process will be examined and the iCVD process will be scaled up. The process will also be used to functionalize the surfaces of polymeric membranes. These membranes have monodisperse pore distributions and vary in porosity, length, and diameter. iCVD will be used to coat these membranes with a low surface energy (10 mN/m) fluoropolymer that renders the membranes both hydrophobic and oleophobic. Contact angle measurements have been used to show that the hydrophobicity of the coated membrane is much larger than the uncoated membrane and x-ray photoelectron spectroscopy has been used to verify the presence of fluorine in the coated membranes. Dynamic contact angle measurements show a low hysteresis indicating that the internal pore surfaces are coated with the fluoropolymer. We are currently studying the depth of penetration of the coating as a function of pore diameter, pore length, and coating thickness using an electron microprobe.