In the feed zone of a centrifuge, fragile biomaterials may be broken, and this results in a decrease in centrifuge separation efficiency and the possibility that small fine particles may affect the following separation steps, by virtue for example of fouling in chromatographic processes. In operation, the USD device is used to generate the equivalent energy dissipation rates to those prevailing in the feed zone of the centrifuge. The separation capacity was mimicked using a laboratory-scale centrifuge. Results are presented that show how the clarification of solids in the large-scale centrifuge process can be predicted using the combination of USD device and the lab-scale centrifuge.
Pumps are a common method for the transport of fluid within bioprocesses and to generate the required pressures for membrane or chromatographic processes. Computational Fluid Dynamics analysis shows that the volume of high shear region in a positive displacement rotary vane pump is tiny compared to the volume of processed materials. However, in the USD device, the ratio of the volume of high shear region to the working volume is much higher than that in the pump. This means that processing biomaterials at the USD device with a short time can be represented for that in the pump operation for a long process time. Experiments using mammalian cells support the theoretical analysis.
In conclusion, only a small amount of biomaterials are needed at the USD device and the process time is relatively short, but it can be used to predict the shear damage in large-scale operations.